Template:Physical constants
This template provides easy inclusion of the latest CODATA recommended values of physical constants in articles. It gives the most recent values published, and will be updated when newer values become available, which is typically every four years.
The values have been updated to the CODATA 2018 values. This includes the 2019 redefinition of SI base units, which made the values of several constants exact (e.g. e), whereas some previously exactly defined constants acquired an uncertainty (e.g. μ0).
Usage
Arguments
symbol
- If set to
yes
, the value is preceded by the symbol of the constant, followed by ≈ or = depending on whether or notround
is set. round
- If omitted, the value is shown along with its standard uncertainty. If set to an integer n, the value is rounded to the first n digits after the decimal point (retaining trailing zeros).
unit
- If set to
no
, the unit of measurement is not shown. ref
- If set to
no
, no reference is given. If set toonly
, only the reference is given. after
- Text (e.g. punctuation) to be shown after the constant before the reference.
runc
- If set to
yes
, this will provide only the relative standard uncertainty of the value and its reference.
Available constants
Code | Constant | Value | Relative standard uncertainty |
---|---|---|---|
a0
|
Bohr radius | a0 = 5.29177210903(80)×10−11 m | ur(a0) = 1.5×10−10[1] |
alpha
|
fine-structure constant | α = 7.2973525693(11)×10−3 | ur(α) = 1.5×10−10[2] |
A90
|
conventional ampere | A90 = 1.00000008887... A | ur(A90) = 0[3] |
atm
|
standard atmosphere | atm = 101325 Pa | ur(atm) = 0[4] |
bwien
|
Wien wavelength displacement law constant | b = 2.897771955...×10−3 m⋅K | ur(b) = 0[5] |
bwien'
|
Wien frequency displacement law constant | b′ = 5.878925757...×1010 Hz⋅K−1 | ur(b′) = 0[6] |
c
|
speed of light | c = 299792458 m/s | ur(c) = 0[7] |
c1
|
first radiation constant | c1 = 3.741771852...×10−16 W⋅m2 | ur(c1) = 0[8] |
c1L
|
first radiation constant for spectral radiance | c1L = 1.191042972...×10−16 W⋅m2⋅sr−1 | ur(c1L) = 0[9] |
c2
|
second radiation constant | c2 = 1.438776877...×10−2 m⋅K | ur(c2) = 0[10] |
C90
|
conventional coulomb | C90 = 1.00000008887... C | ur(C90) = 0[11] |
DnuCs
|
hyperfine structure transition frequency of caesium-133 | Δν(133Cs)hfs = 9192631770 Hz | ur(Δν(133Cs)hfs) = 0[12] |
e
|
elementary charge | e = 1.602176634×10−19 C | ur(e) = 0[13] |
Eh
|
Hartree energy | Eh = 4.3597447222071(85)×10−18 J | ur(Eh) = 1.9×10−12[14] |
EheV
|
Hartree energy in eV | Eh = 27.211386245988(53) eV | ur(Eh) = 1.9×10−12[15] |
eps0
|
vacuum electric permittivity | ε0 = 8.8541878128(13)×10−12 F⋅m−1 | ur(ε0) = 1.5×10−10[16] |
eV
|
electronvolt | eV = 1.602176634×10−19 J | ur(eV) = 0[17] |
F
|
Faraday constant | F = 96485.33212... C⋅mol−1 | ur(F) = 0[18] |
F90
|
conventional farad | F90 = 0.99999998220... F | ur(F90) = 0[19] |
G
|
gravitational constant | G = 6.67430(15)×10−11 m3⋅kg−1⋅s−2 | ur(G) = 2.2×10−5[20] |
G0
|
conductance quantum | G0 = 7.748091729...×10−5 S | ur(G0) = 0[21] |
g0
|
standard acceleration of gravity | g0 = 9.80665 m⋅s−2 | ur(g0) = 0[22] |
ge
|
electron g-factor | ge− = −2.00231930436256(35) | ur(ge−) = 1.7×10−13[23] |
GF/hbarc3
|
Fermi coupling constant | GF/(ħc)3 = 1.1663787(6)×10−5 GeV−2 | ur(GF/(ħc)3) = 5.1×10−7[24] |
gmu
|
muon g-factor | gμ− = −2.0023318418(13) | ur(gμ−) = 6.3×10−10[25] |
gp
|
proton g-factor | gp = 5.5856946893(16) | ur(gp) = 2.9×10−10[26] |
h
|
Planck constant | h = 6.62607015×10−34 J⋅s | ur(h) = 0[27] |
H90
|
conventional henry | H90 = 1.00000001779... H | ur(H90) = 0[28] |
hbar
|
reduced Planck constant | ħ = 1.054571817...×10−34 J⋅s | ur(ħ) = 0[29] |
h/2me
|
quantum of circulation | h/2me = 3.6369475516(11)×10−4 m2⋅s−1 | ur(h/2me) = 3.0×10−10[30] |
invalpha
|
inverse fine-structure constant | 1/α = 137.035999084(21) | ur(1/α) = 1.5×10−10[31] |
invG0
|
inverse conductance quantum | G0−1 = 12906.40372... Ω | ur(G0−1) = 0[32] |
k
|
Boltzmann constant | k = 1.380649×10−23 J⋅K−1 | ur(k) = 0[33] |
KJ
|
Josephson constant | KJ = 483597.8484...×109 Hz⋅V−1 | ur(KJ) = 0[34] |
KJ90
|
conventional value of Josephson constant | KJ-90 = 483597.9×109 Hz⋅V−1 | ur(KJ-90) = 0[35] |
lP
|
Planck length | lP = 1.616255(18)×10−35 m | ur(lP) = 1.1×10−5[36] |
MC12
|
molar mass of carbon-12 | M(12C) = 11.9999999958(36)×10−3 kg⋅mol−1 | ur(M(12C)) = 3.0×10−10[37] |
me
|
electron mass | me = 9.1093837015(28)×10−31 kg | ur(me) = 3.0×10−10[38] |
meDa
|
electron mass in daltons | me = 5.48579909065(16)×10−4 Da | ur(me) = 2.9×10−11[39] |
mmu
|
muon mass | mμ = 1.883531627(42)×10−28 kg | ur(mμ) = 2.2×10−8[40] |
mn
|
neutron mass | mn = 1.67492749804(95)×10−27 kg | ur(mn) = 5.7×10−10[41] |
mnDa
|
neutron mass in daltons | mn = 1.00866491595(49) Da | ur(mn) = 4.8×10−10[42] |
mP
|
Planck mass | mP = 2.176435(24)×10−8 kg | ur(mP) = 1.1×10−5[43] |
mp
|
proton mass | mp = 1.67262192369(51)×10−27 kg | ur(mp) = 3.1×10−10[44] |
mpome
|
proton-to-electron mass ratio | mp/me = 1836.15267343(11) | ur(mp/me) = 6.0×10−11[45] |
mtau
|
tau mass | mτ = 3.16754(21)×10−27 kg | ur(mτ) = 6.8×10−5[46] |
Mu
|
molar mass constant | Mu = 0.99999999965(30)×10−3 kg⋅mol−1 | ur(Mu) = 3.0×10−10[47] |
mu
|
atomic mass constant | mu = 1.66053906660(50)×10−27 kg | ur(mu) = 3.0×10−10[48] |
muc2
|
atomic mass constant energy equivalent | muc2 = 1.49241808560(45)×10−10 J | ur(muc2) = 3.0×10−10[49] |
mueV
|
atomic mass constant energy equivalent in MeV | muc2 = 931.49410242(28) MeV | ur(muc2) = 3.0×10−10[50] |
mu0
|
vacuum magnetic permeability | μ0 = 1.25663706212(19)×10−6 N⋅A−2 | ur(μ0) = 1.5×10−10[51] |
muB
|
Bohr magneton | μB = 9.2740100783(28)×10−24 J⋅T−1 | ur(μB) = 3.0×10−10[52] |
muN
|
nuclear magneton | μN = 5.0507837461(15)×10−27 J⋅T−1 | ur(μN) = 3.1×10−10[53] |
mW/mZ
|
W-to-Z mass ratio | mW/mZ = 0.88153(17) | ur(mW/mZ) = 1.9×10−4[54] |
NA
|
Avogadro constant | NA = 6.02214076×1023 mol−1 | ur(NA) = 0[55] |
NAh
|
molar Planck constant | NAh = 3.990312712...×10−10 J⋅Hz−1⋅mol−1 | ur(NAh) = 0[56] |
ohm90
|
conventional ohm | Ω90 = 1.00000001779... Ω | ur(Ω90) = 0[57] |
Phi0
|
magnetic flux quantum | Φ0 = 2.067833848...×10−15 Wb | ur(Φ0) = 0[58] |
R
|
molar gas constant | R = 8.314462618... J⋅mol−1⋅K−1 | ur(R) = 0[59] |
re
|
classical electron radius | re = 2.8179403262(13)×10−15 m | ur(re) = 4.5×10−10[60] |
Rinf
|
Rydberg constant | R∞ = 10973731.568160(21) m−1 | ur(R∞) = 1.9×10−12[61] |
RK
|
von Klitzing constant | RK = 25812.80745... Ω | ur(RK) = 0[62] |
RK90
|
conventional value of von Klitzing constant | RK-90 = 25812.807 Ω | ur(RK-90) = 0[63] |
sigma
|
Stefan–Boltzmann constant | σ = 5.670374419...×10−8 W⋅m−2⋅K−4 | ur(σ) = 0[64] |
sigmae
|
Thomson cross section | σe = 6.6524587321(60)×10−29 m2 | ur(σe) = 9.1×10−10[65] |
TP
|
Planck temperature | TP = 1.416785(16)×1032 K | ur(TP) = 1.1×10−5[66] |
tP
|
Planck time | tP = 5.391247(60)×10−44 s | ur(tP) = 1.1×10−5[67] |
V90
|
conventional volt | V90 = 1.00000010666... V | ur(V90) = 0[68] |
VmSi
|
molar volume of silicon | Vm(Si) = 1.205883199(60)×10−5 m3⋅mol−1 | ur(Vm(Si)) = 4.9×10−8[69] |
W90
|
conventional watt | W90 = 1.00000019553... W | ur(W90) = 0[70] |
Z0
|
characteristic impedance of vacuum | Z0 = 376.730313668(57) Ω | ur(Z0) = 1.5×10−10[71] |
Examples
{{Physical constants|c|unit=no|after= [[metre per second|metres per second]].}}
- 299792458 metres per second.[7]
{{Physical constants|mu0|symbol=yes}}
- μ0 = 1.25663706212(19)×10−6 N⋅A−2[51]
{{Physical constants|G|symbol=yes}}
- G = 6.67430(15)×10−11 m3⋅kg−1⋅s−2[20]
{{Physical constants|hbar|round=2|symbol=yes}}
- ħ ≈ 1.05×10−34 J⋅s[29]
The relative standard uncertainty of ''m''<sub>u</sub> is {{Physical constants|mu|runc=yes|after=.}}
- The relative standard uncertainty of mu is 3.0×10−10.[48]
For the electron mass, {{Physical constants|me|runc=yes|symbol=yes|ref=no}}.
- For the electron mass, ur(me) = 3.0×10−10.
NIST publishes the CODATA value of the [[elementary charge]].{{Physical constants|e|ref=only}}
- NIST publishes the CODATA value of the elementary charge.[13]
See also
{{CODATA2010}}
References
- ↑ "2018 CODATA Value: Bohr radius". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: fine-structure constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: conventional value of ampere-90". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-06-01.
- ↑ "2018 CODATA Value: standard atmosphere". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: Wien wavelength displacement law constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: Wien frequency displacement law constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ 7.0 7.1 "2018 CODATA Value: speed of light in vacuum". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: first radiation constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: first radiation constant for spectral radiance". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: second radiation constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: conventional value of coulomb-90". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-06-01.
- ↑ "2018 CODATA Value: hyperfine transition frequency of Cs-133". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-08-18.
- ↑ 13.0 13.1 "2018 CODATA Value: elementary charge". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: Hartree energy". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: Hartree energy in eV". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-09-01.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: vacuum electric permittivity". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: electron volt". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: Faraday constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: conventional value of farad-90". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-06-01.
- ↑ 20.0 20.1 "2018 CODATA Value: Newtonian constant of gravitation". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: conductance quantum". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: standard acceleration of gravity". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: electron g factor". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2020-03-13.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: Fermi coupling constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: muon g factor". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: proton g factor". The NIST Reference on Constants, Units, and Uncertainty. NIST. June 2015. Retrieved 2019-03-08.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: Planck constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: conventional value of henry-90". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-06-01.
- ↑ 29.0 29.1 "2018 CODATA Value: reduced Planck constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-08-28.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: quantum of circulation". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: inverse fine-structure constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: inverse of conductance quantum". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: Boltzmann constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: Josephson constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: conventional value of Josephson constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: Planck length". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: molar mass of carbon-12". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: electron mass in u". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: electron mass". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2020-06-21.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: muon mass". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: neutron mass". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-08-23.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: neutron mass in u". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2020-06-24.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: Planck mass". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: proton mass". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: proton-electron mass ratio". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: tau mass". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: molar mass constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ 48.0 48.1 "2018 CODATA Value: atomic mass constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: atomic mass constant energy equivalent". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-07-21.
- ↑ "2018 CODATA Value: atomic mass constant energy equivalent in MeV". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-07-21.
- ↑ 51.0 51.1 "2018 CODATA Value: vacuum magnetic permeability". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: Bohr magneton". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: nuclear magneton". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: W to Z mass ratio". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-12-21.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: Avogadro constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: molar Planck constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: conventional value of ohm-90". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-06-01.
- ↑ "2018 CODATA Value: magnetic flux quantum". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: molar gas constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: classical electron radius". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: Rydberg constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: von Klitzing constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: conventional value of von Klitzing constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: Stefan–Boltzmann constant". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: Thomson cross section". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
{{cite web}}
: Cite has empty unknown parameter:|month=
(help) - ↑ "2018 CODATA Value: Planck temperature". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: Planck time". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-05-20.
- ↑ "2018 CODATA Value: conventional value of volt-90". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-06-01.
- ↑ "2018 CODATA Value: molar volume of silicon". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-06-23.
- ↑ "2018 CODATA Value: conventional value of watt-90". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-06-01.
- ↑ "2018 CODATA Value: characteristic impedance of vacuum". The NIST Reference on Constants, Units, and Uncertainty. NIST. 20 May 2019. Retrieved 2019-10-31.